Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Portal frames

The adjustments to αcr in the calculation of αcr,est allow for what phenomena?

The high moment and shear combined
The flexibility of the structure
The axial load in the columns and rafters
The base fixity

What is the primary function of an eaves haunch?

To facilitate a bolted connection
To increase the shear resistance at the support
To increase the bending resistance of the rafter section
To reduce deflections

What best describes a portal frame structure?

Frames of simple construction
3-d continuous structures
Continuous frames in-plane, braced in the longitudinal direction
Continuous frames, braced in-plane

When might the inside of a gable column be in compression?

When the gable is the leeward face of the building
When the wind direction is parallel to the gable
When there is a large internal pressure
When the gable is on the windward face of the building

Why are Anti-sag systems used with purlins?

To control the vertical deflection of the purlins
To control deflection down the slope, and assist the alignment of the purlins
To provide restraint to the bottom flange of the purlin in an uplift combination of actions
So that the manufacturer's warranty is not invalidated

What steps are effective in reducing the calculated deflections at SLS?

Modelling the stiffness of nominally pinned bases
Using higher strength steels
Using members with a higher inertia
Adding restraints

How can second-order effects in portal frames be allowed for?

By using a second-order analysis
By amplifying the lateral loads
By using S355 steel
By down-rating member resistance by 10%

How is a moment-resisting base commonly detailed for the fire condition, if necessary?

With a thicker base plate
With more holding down bolts
Set into a pocket cast in the base
Provided with stiffeners

When might a Morris stiffener be required in a haunch connection?

When the vertical shear exceeds the resistance of the rafter web
When the panel shear exceeds the resistance of the column web
Whenever a compression stiffener is provided
To provide a fixing point for the vertical bracing and the eaves member

How should purlins be located?

At spaces less than the maximum spaces specified by the cladding manufacturer
Spaced equally between the eaves and the apex
Judiciously, to suit the restraint to the rafter
At 1.75m centres